Jet 756151 wh-45t - 45" english wheel User Guide

Page of 48
 
18 
Precision Miter Gauge 
Setting the miter gauge angle 
Referring to Figure 17: 
The precision miter gauge has a rack and pinion 
adjustment for setting the angle. To operate: 
1.  Slide the miter gauge into one of the slots on 
the table top. 
2. Loosen 
lock handle (A). 
To adjust the body (B) of the miter gauge to the 
desired angle: 
3. Pull 
the 
spring-loaded knob (C) out and turn 
until the body (B) of the miter gauge is at the 
desired angle as indicated on the scale. 
4. Tighten 
the 
lock handle (A). 
Indent settings 
There are indents at the 0º, 30º and 45º right and 
left positions. At these settings, release the 
knob (C) to engage the stop rod. Then tighten the 
lock handle (A). 
Note: Do not rely solely on the indents for an 
accurate setting. After the stop rod engages at the 
0º, 30º and 45º positions, make a fine adjustment 
with the knob (C) by pulling out and rotating, if 
necessary, setting it against the scale indicator. 
Extension plate 
The extension plate (D) can be adjusted by sliding 
to the right or left or removed entirely.  
To adjust – loosen two lock handles (E), position 
the extension plate and tighten the lock handles.  
To remove – slide the extension plate completely 
off and remove the lock handles (E) and mounting 
hardware. 
Calibrating the miter gauge 
1.  Place the miter gauge in one of the slots (H) 
on the table top. 
2.  Set the miter gauge to 90º (0º setting on the 
scale) by loosening the lock handle (A), then 
pulling the spring-loaded knob (C) out and 
turning the body (B) until 0º is indicated on 
the scale (F). 
3.  Measure the accuracy of the gauge against 
the slot with a combination square. 
If adjustment is necessary: 
4. Adjust 
the 
body (B) until it is perfectly square 
(90º) to the miter slot (H). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 17 
 
 
 
 
 
5. Tighten 
the 
lock handle (A). 
Verify that the scale indicator (G) reads 0º. If 
further adjustment is necessary: 
6. Loosen the screw (F) and adjust the 
indicator (G) until it reads 0º 
7. Tighten 
the 
screw (F).