Figure 6 
8.6  Length stop 
Refer to Figure 7. 
1.  Screw the lower rod into the threaded hole in 
the base. Orient the rod so that the graduated 
scale is visible, and tighten the hex nut with a 
19mm wrench to secure. 
2.  Calibrate the length stop: Lower the blade, and 
loosen the knobs on the rod holder. Then slide 
the upper rod into contact with the blade, and 
adjust the rod holder so that its left edge aligns 
with the zero. Re-tighten the top knob to 
secure the zero setting. 
 
Figure 7 
9.0  Electrical connections 
 Electrical connections must 
be made by a qualified 
electrician in compliance with all relevant 
codes. This machine must be properly 
grounded to help prevent electrical shock and 
possible fatal injury.
 
On all models, if a machine is being hard-wired to a 
panel, make sure a disconnect is available for the 
operator. During hard-wiring of the machine, make 
sure the fuses have been removed or the breakers 
have been tripped in the circuit to which the cold 
saw will be connected. Place a warning placard on 
the fuse holder or circuit breaker to prevent it being 
turned on while the machine is being wired. 
See table 2 for recommended circuit sizes for your 
particular model. NOTE: Local codes take 
precedence over recommendations.
 
Recommended circuit size 
CS-275      (3PH 230V)
10A 
CS-275-1   (1PH,115/230V) 
20A 
CS-315      (3PH 230V)
15A 
CS-315-1   (1PH, 230V)
20A 
Table 2 
9.1  Three-phase models 
The  CS-275 (3-phase) and CS-315 (3-phase) are 
rated for 230-volt only power. They are not 
supplied with a plug. You may either install a 
proper 230V UL/CSA listed plug, or “hardwire” the 
machine directly to a service panel. 
After wiring, make sure that the blade rotates in the 
proper direction. If it does not, reverse two of the 3-
phase wires on the supply input.  
9.2  Single-phase models 
The CS-315-1 (single phase) is rated for 230-volt 
only power. It is not supplied with a plug. You may 
either install a proper 230V UL/CSA listed plug, or 
“hardwire” the machine directly to a service panel. 
The  CS-275-1 (single phase) is rated for 
115/230V, prewired for 115V and supplied with a 
120-volt rated plug. It may be converted to 230V. 
See section 9.3. 
9.3  Voltage conversion (model CS-
275-1 only) 
To convert from 115V to 230V:  
1.  Remove the panel from the control box.  
2.  On the transformer, reconnect the L11 line 
from the 120V terminal to the 230V terminal 
(A, Figure 8). 
 
Figure 8 
3.  Replace the 20 amp fuses with 10 amp fuses 
in the first two fuse holders (B, Figure 8).