Aethra d2000pro User Guide

Page of 88
Quick Guide 
VX2000 
 
10 
 
 
 
GB 
• 
NO, the device guarantees and controls the C108, C107, C105, C106 and C109i 
criteria  
• 
YES, the management and the check of these criteria, between DTE and DCE, is 
disabled  
Clock RX: Define the type of clock used to receive data; with CLOCK RX: 
LOOPED, the device samples data received with the clock coming from DTE 
(C113). Only DCE. 
 
In DCE mode, the clock TX is fixed at “INSIDE”, whereas in DTE 
mode, the device uses the clock coming from the DCE over 
C114 criterion. 
Loop3 (C141): Set “YES” to ask the DCE to perform a  local loop (LL) of the data. 
Only DTE. 
 
The LL (local loop) request  is supported by V.35 and V.36 
interfaces only. 
1.3  UNFRAMED BER Test 
In order to run a line quality test, select from the manual test menu, the 
UNFRAMED BER  and set the following parameters: 
 
 
Duration: Choose the duration of the test. Select from the defined list or define your 
own duration 
Pass/Fail test: Choose the BER value. This value is used to determine the pass or 
fail test condition. Selecting G.821, the result is compared  with the quality 
performance required by G.821. Only for line rate 64Kbit/s. 
Error injection: Choose the BER value used for manual or automatic bit error 
injection 
Bit sequence: Set the pseudo-random pattern to be used. Select from the list