Timeouts
Specifies the amount of time 
the MFP waits to return to the 
home screen, receive an end-
of-job message, or receive 
additional bytes of data from 
the computer.
Note: Wait Timeout is only 
available when using 
PostScript emulation. This 
menu value has no effect on 
PCL emulation print jobs.
Standby Mode
Disabled
1–240 (15*)
Touch the LCD screen or press any of the 
hard buttons to exit (wake up) from this mode.
Disabled—Disables Standby Mode.
1–240—Specifies the amount of time in 
minutes that the MFP waits before returning 
to the home screen.
Power Saver Mode
Disabled
2–240 (60*)
It sets the number of minutes that pass after 
exiting Standby Mode before the MFP goes 
into a reduced power state called Power 
Saver Mode.
If Standby Mode is disabled, which is 
considered a setting of 0, then Power Saver 
Mode is the number of minutes of inactivity 
that occurs before entering Power Saver 
Mode.
Print the menu settings page to determine the 
current Power Saver setting. When the MFP is 
in Power Saver Mode, it is still ready to 
receive print jobs. 
Disabled—Disables Power Saver Mode. 
Disabled is not available if Energy Conserve is 
set to On.
2–240 (60*)—Specifies the amount of time 
after exiting Standby Mode or after finishing a 
print job before the MFP goes into Power 
Saver mode.
For example, select 15 to put the MFP in 
Power Saver mode 15 minutes after it finishes 
a print job. This uses much less energy, but 
requires more warm-up time for the MFP. 
Select 15 if your MFP shares an electrical 
circuit with room lighting and you notice lights 
flickering. Select a high value if the MFP is in 
constant use. Under most circumstances, this 
keeps the MFP ready to print with minimum 
warm-up time. Select a value between 1 and 
240 minutes for a balance between energy 
consumption and a shorter warm-up period.
Note: When the MFP enters Power Saver 
Mode, for the entire duration in this mode, 
Screen Brightness is set to 15. Touch the LCD 
screen or press any of the hard buttons to exit 
(wake up) from this mode.
Screen Timeout
15–300 (30*)
Disabled—Disables Screen Timeout.
15–300—Specifies the amount of time in 
seconds before the control panel returns to 
the home screen due to inactivity.
Menu item