Hitachi P7K500 Specification Guide

Page of 278
 
HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 
99 
8.21.2.3.3 
Format of SCT Status Response   
Byte Type  Field 
Name 
Value 
Description 
1:0 
Word 
Format Version 
0003h 
Status Response format version number 
3:2 Word SCT 
Version   
Manufacturer’s vendor specific 
implementation version number 
5:4 
Word 
SCT 
Spec. 
0001h 
Highest level of SCT Technical Report 
supported 
9:6 
DWord 
Status Flags 
 
Bit 0 : Segment Initialized Flag 
 If this bit is set to 1, an LBA Segment 
Access command write to all LBAs of the 
drive has completed without error. This bit 
shall be cleared to 0 when any user LBA is 
written, even if write cache is enabled. This 
bit is alse cleared if the capacity of the drive 
is changed via SETMAX, SETMAX EXT or 
DCO. This bit is preserved through a power 
cycle. 
Bit 1-31 : Reserved 
10 
Byte 
Drive Status 
 
0 = Active waiting for a command   
1 = Stand-by 
2 = Sleep 
3 = DST executing in background 
4 = SMART ODC executing in background 
5 = SCT executing in background 
13:11 Byte[3] reserved 
00h 
 
15:14 Word  Extended 
Status 
Code 
 Status 
Of 
last 
SCT command issued. 
FFFFh if SCT command executing in 
background. 
17:16 
Word 
Action Code 
 
Action code of last SCT command issued. If 
the Extended Status Code is FFFFh, this is 
the Action Code of the command that is 
current executing. 
19:18 
Word 
Function 
Code 
 
Function code of last SCT command 
issued. If the Extended Status Code is 
FFFFh, this is the Function Code of the 
command that is current executing. 
39:20 Byte[20] reserved 
00h 
 
47:40 
QWord 
LBA 
 
Current LBA of SCT command executin in 
background. If there is no command 
currently executing in the background, this 
field is undefined. 
199:48   Byte[152]   
00h 
 
200 
Byte 
HDA 
Temp 
 
Current HDA temperature in degrees 
Celsius. This is a 2’s complement number. 
80h indicates that this value is invalid. 
201 
Byte 
Min 
Temp 
 
Minimum HDA temperature in degrees 
Celsius. This is a 2’s complement integer. 
80h indicates that this value is invalid. 
202 
Byte 
Max 
Temp 
 
Maximum HDA temperature in degrees 
Celsius. This is a 2’s complement number. 
80h indicates that this value is invalid. 
203 
Byte 
Life 
Min 
Temp 
 
Minimum HDA temperature in degrees 
Celsius seen for the life of the device. This 
is a 2’s complement integer. 80h indicates 
that this value is invalid. 
204 
Byte 
Life 
Max 
Temp 
 
Maximum HDA temperature in degrees 
Celsius seen for the life of the drive. This is 
a 2’s complement number. 80h indicates 
that this value is invalid.