The remote sense return (ReturnS) is able to regulate out a minimum of 200mV drop in the 
power ground return. The current in any remote sense line is less than 5mA to prevent voltage 
sensing errors. The power supply operates within specification over the full range of voltage 
drops from the power supply’s output connector to the remote sense points. 
3.1.5.5 
Power Module Output Power / Currents 
The following table defines power and current ratings for this 600W power supply. The 
combined output power of all outputs does not exceed the rated output power. Below are load 
ranges for each of the two power supply power levels. The power supply meets both static and 
dynamic voltage regulation requirements for the minimum loading conditions. 
Table 18. Load Ratings 
 
Load Range 1 (Maximum System Loading) 
 
Voltage 
Minimum 
Continuous Load 
Maximum Continuous 
Load
1, 3
 
Peak Load
2, 4, 5
 
+3.3V
6
 
1.5 A 
20 A 
 
+5V
6
 
5.0 A 
24 A 
 
+12V1 
1.5 A 
15 A  
18 A  
+12V2 
1.5 A 
15 A  
18 A  
+12V3 
1.5 A 
16 A  
18 A 
+12V4 
1.5 A 
16 A 
18 A 
-12V 
0 A 
0.5 A 
 
+5VSB 
0.1 A 
2.0 A 
 
 
 
Load Range 2 (Light System Loading) 
 
Voltage Minimum 
Continuous Load 
Maximum 
Continuous Load 
Peak Load
5
 
+3.3V
6
 
0.5 A 
9.0 A 
 
+5V
6
 
2.0 A 
7.0 A 
 
+12V1 
0.5 A 
5.0 A 
7.0 A  
+12V2 
0.5 A 
5.0 A 
7.0 A  
+12V3 
2.0 A 
6.0 A 
 
+12V4 
0.5 A 
5.0 A 
 
-12V 
0 A 
0.5 A 
 
+5VSB 
0.1 A 
2.0 A 
 
Notes:  
A. 
Maximum continuous total DC output power should not exceed 600 W. 
B. 
Peak load on the combined 12-V output shall not exceed 48 A. 
C. 
Maximum continuous load on the combined 12-V output shall not exceed 43 A. 
D. 
Peak total DC output power should not exceed 660 W. 
E. 
Peak power and peak current loading shall be supported for a minimum of 12 
seconds. 
F. 
Combined 3.3V/5V power shall not exceed 140 W.