Intel SC5650BCDP User Manual

Page of 71
Cooling Sub-System 
Intel
®
 Server System SC5650BCDP TPS 
 
Intel order number: E80367-002 
Revision 1.5 
 
30 
 
4.  Cooling Sub-System 
4.1  Fan Configuration 
The cooling sub-system of the Intel
®
 Server System SC5650BCDP consists of one 120mm 
chassis fan, one 120mm PCI fan and one 92mm drive bay fan. The 4-wire chassis fan provides 
cooling at the rear of the chassis by drawing fresh air into the chassis from the front and 
exhausting warm air out the system. This fan is PWM controlled. The server board S5500BC 
monitors several temperature sensors and adjusts the duty cycle of the PWM signal to drive the 
fan at the appropriate speed. The 4-wire PCI fan behind the PCI card guide provides cooling by 
drawing fresh air from the front of the chassis through PCI fan guide and exhausting it into the 
PCI bay area. The 4-wire 92-mm drive bay fan provides additional cooling to the drive bay by 
drawing fresh air from the front of the chassis through drive bay area and exhausting warm air 
out the bay area. 
Removal and insertion of the two 120-mm fans or 92-mm fan can be done without tools. The 
power supply internal fan assists in drawing air through the peripheral bay area, through the 
power supply and exhausting it out the rear of the system. The Intel
®
 Server System 
SC5650BCDP is optimized for the Intel
®
 server board S5500BC that using an active CPU 
heatsink solution.  
If an optional hot-swap drive bay is installed, a 4-wire 92-mm fan is included with the mounting 
bracket kit for installation onto the drive bay. This fan has a PWM circuit that allows the server 
board to control the fan speed based on sensor readings of ambient temperature. 
The front panel of the Intel
®
 Server System SC5650BCDP provides a TMP75 temperature 
sensor for BMC control. The Intel
® 
Server Board S5500BC BMC controller may use the TMP75 
sensor to adjust fan speeds according to air intake temperatures. Refer to the Intel
®
 Server 
Board S5500BC Technical Product Specification
 for configuring information.  
4.2  Server Board Fan Control 
The fans provided in the Intel
®
 Server System SC5650BCDP contain a tachometer signal that 
can be monitored by the server management subsystem for the Intel
®
 Server Boards S5500BC. 
See Intel
®
 Server Boards S5500BC Technical Product Specification for details on how this 
feature works. 
4.3  Cooling Solution 
Air should flow through the system from front to back, as indicated by the arrows in the following 
figure.