Nortel 1000 User Guide
64
Installation and configuration
Procedure 3
Configure a dual-card conference
Step
Action
1
Install the two cards and their Ethernet adapters identical to
single-card installation. See
single-card installation. See
Note: There is no need for the two cards to be next to each
other in the shelf or cabinet.
other in the shelf or cabinet.
2
Busy and Return to Service (RTS) the two cards in the IPE PM level
of the MAP terminal.
of the MAP terminal.
3
For each card, connect a VT100 terminal to the card and enter the
keycode information, including the appropriate number of ports. Wait
for each card to verify the keycode information.
keycode information, including the appropriate number of ports. Wait
for each card to verify the keycode information.
4
For each card, log into the card through the CLI (default login:
admin). Enter the System Attributes Editor, enter
admin). Enter the System Attributes Editor, enter
sa
then
sy
, and
modify the following information:
The subnet mask, the gateway address, and the IP address
Note: After entering the Ethernet information, the CLI asks if
you want to restart the cards. Select YES at this point.
you want to restart the cards. Select YES at this point.
5
From a PC, ping each ICB card to make sure that they have a correct
connection to the LAN. To ping an IP card, perform the following:
connection to the LAN. To ping an IP card, perform the following:
a. Click on the Start button and select Run from the Start Menu.
b. In the Open: field, enter
ping <IP address>
where <IP
address> is the IP address of one of the ICB cards.
c. Click the OK button, and observe the DOS window that opens.
If you receive the message: "Reply from <IP address>...", you
have set up the LAN connection correctly and you can continue.
If you receive the message: "Request timed out", there is a
problem with the LAN connection.
have set up the LAN connection correctly and you can continue.
If you receive the message: "Request timed out", there is a
problem with the LAN connection.
6
Configure the DNs for the dual-card configuration.
7
Configure each port on the two new cards as an M2616 set. See
. Refer
to SERVORD information in
.
8
Open up the web browser on your PC. In the URL field of the
browser, enter the following:
browser, enter the following:
<IP address>
where < IP address>
is the ICB IP address.
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100
Nortel Integrated Conference Bridge: Service Implementation Fundamentals
NN43001-558/555-4001-135
01.02
Standard
ICB Release 4
20 June 2007
Copyright © 2007, Nortel Networks
.