Installation and configuration
Figure 27
Terminal connection through the Ethernet Adapter
Procedure 5
Access the ICB directly
Step
Action
1
Position the Maintenance terminal on a desk near the system.
2
Verify that the Ethernet Adapter card is on the I/O panel as described
in
.
3
Plug the terminal cable DB-9 female connector into the DB-9 male
connector on the Ethernet Adapter card on the I/O panel.
4
Plug the DB-25 male connector at the other end of the terminal
cable into the RS-232 connector on the terminal. A nullmodem is
not required. If a gender changer is required, purchase one from
a local electronics store.
—End—
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100
Nortel Integrated Conference Bridge: Service Implementation Fundamentals
NN43001-558/555-4001-135
01.02
Standard
ICB Release 4
20 June 2007