Extreme x250e-24t Installation Instruction

Page of 220
Installing Summit External Power Supplies
 
Summit Family Switches Hardware Installation Guide
130
To rack-mount each EPS-LD unit: 
1
Place the EPS-LD unit upright on a stable surface, with the side you want to face to the front of the 
switch toward you.
2
Remove the mounting bracket kit from the packaging.
3
Attach the mounting brackets as follows:
a
Place a mounting bracket over the mounting holes on one side of the unit (see 
b
Insert the provided screws and fully tighten them using a screwdriver.
Figure 98: Attaching the Mounting Bracket 
c
Repeat steps 
 for the other side of the EPS-LD unit.
4
Slide the EPS-LD into a 19-inch rack and secure it using appropriate rack-mount screws.
NOTE
Extreme Networks recommends that you position the EPS-LD so that the output connectors are on the same side 
as the external connector on the connecting switch. If you mount the EPS-LD with the connectors facing in the 
opposite direction from the Summit switch connector, leave at least 1 U between the switch and the EPS-LD 
through which to slide the power cords. Do not route the power cords around the equipment rack.
Connecting the EPS-LD to the Switch
CAUTION
Do not attach the AC power cord to the EPS-LD unit until the unit is properly grounded at the electrical outlet and 
the redundant power supply cord is connected.
One end of the EPS-LD cord has a keyed connector to ensure correct alignment of the connector 
(
). The key is a plastic tab on the cord connector housing that fits into the EPS-LD unit to 
ensure correct alignment of the connector. 