Intermec 10I2 User Guide

Page of 121
72 
EasyLAN User’s Guide
Chapter 6 — Advanced Confi guration
alerts Section 
Objects enabled by default
-  cutter  
Alerts if cutter error.
-  headlifted  
Alerts if head lifted and printfeed.
-  ribbonend   Alerts if ribbon end and printfeed.
-  paperend  
Alerts if paper end and printfeed.
-  ribbonlow  
Alerts if ribbon low and printfeed.
-  paperlow  
Alerts if paper low and printfeed. 
Objects disabled by default
-  lts    
Sends alert when the printer is waiting for a label to  
  
be 
taken.
-  pause  
Sends alert if a batch printing is paused.
-  setup  
Sends alert if Setup Mode is entered via the printers  
  
internal 
keyboard.
-  error   
Sends alert when a Fingerprint/Direct Protocol error  
 
 
occurs (before giving control to the error-handler).
-  break  
Sends alert if the user breaks the program or if an error  
  
breaks 
Th
  e running program, that is, it is not sent after  
 
 
stop or breakpoint.
-  job-complete  Sends alert when all labels in a print feed batch are  
  
started.
-  odometer 
Alerts on diff erent service intervals depending  
 
 
 
on the odometer count1 value. 
Value Syntax
(enabled|disabled,<integer>,seconds|occurrences,
<text string>)
Example
SETUP "alerts","cutter","(enabled,9,seconds,Error 
- Cutter Error)"
lan1 Section
Objects starting with a dot (.) cannot be read if the current user does 
not have rights to read/set protected lan1 settings. Objects starting with 
a plus sign (+) on the other hand, signify that all users can change the 
setting.
Objects Description
ALERT_REC
 
 
To address. Defi nes to whom the Alert 
messages should be sent.