Intermec cv60 Installation Instruction

Page of 36
3
Troubleshooting Information
Chapter
23
CV60 DC-DC Converter Installation Guide
Electrical Measurements
Voltage
Connector pinout information is provided to allow you to measure
voltage at the input power cable and at either end of the power
output cable.
Continuity
Caution: Cables MUST be disconnected at both
ends before conducting continuity tests.
Thorough continuity testing takes longer than either substitution
or taking voltage measurements. An ohmmeter is sufficient to
diagnose simple opens or shorts.
If fuses blow sporadically, or power supply shut down occurs at
random, you may want to use a megohmmeter to check cables
for high-resistance shorts between wires or between a wire and
the cable shield.
Substitution
Advantages
Component substitution is the most expedient and certain trouble-
shooting technique. It is especially valuable when trying to resolve
intermittent problems.
Disadvantages
You must either have spare parts (power supply and both cables
in this instance) or be prepared to “borrow” components from
another working installation.
When to Substitute
Follow the guidelines in the Troubleshooting chart that follows,
substituting only when directed to do so.
If an installation suffers intermittent input power fuse failures,
or if the power supply shuts down without good cause, do not
hesitate to substitute a known good power supply.