Intermec cv60 Installation Instruction

Page of 36
3
Troubleshooting Information
Chapter
24
CV60 DC-DC Converter Installation Guide
Troubleshooting Charts
The following troubleshooting chart assumes that your computer
or other equipment does not work and that the problem is caused
by the power supply or its associated cables. Follow the procedures
in the tables in the order shown for maximum efficiency.
Power Supply Reset
Where the troubleshooting chart tells you to “reset the power
supply” you must disconnect the input power cable for 10 sec-
onds, then reconnect it. The power supply has automatic over-
voltage, over-current, over-temperature, and short circuit protec-
tion and must be reset by disabling input power whenever any
of these faults activates that protection.
Power Failure Troubleshooting Chart 1
Observe
Result
Meaning
Remedy
LED
Lit
Power supply is
working
Test or substitute output
power cable.
LED
NOT Lit
No output from
power supply
Reset the power supply
LED
NOT Lit
No output from
power supply
Disconnect power output
cable, then reset the power
supply.
LED
Lit (now)
Power supply is
working.
Substitute power output
cable.
Power Failure Troubleshooting Chart 2(assumes steps in
chart above were followed).
Observe
Result
Meaning
Test or Remedy
LED
NOT Lit
No output from
power supply
Test for input voltage.
Voltage
Normal
Power supply
not working.
Replace power supply.
Voltage
NOT
present
No input power
to the power
supply.
Replace inline fuse if
voltage is NOT present at
connector.
Replace input power
cable if input voltage is
still not present at
connector.