Important Precautions
This battery charger is intended to charge only the SONY NP-500
series of battery packs (such as NP-520, NP-500, and NP-F530).
Attach the battery pack firmly.
Charge the battery pack on a flat, vibration-free surface.
The battery pack gradually discharges even if it is fully charged.
Intermec recommends that you charge the battery pack immediately
before use, or at least within a couple of days before use.
Intermec recommends that you remove the battery pack from the
charger within 24 hours after charging is completed.
The temperature range for charging is 0ºC to 40ºC (32ºF to 104ºF).
However, for maximum battery pack efficiency, the recommended
temperature range when charging is 10ºC to 30ºC (50ºF to 86ºF).
Be sure nothing metallic comes into contact with the contacts.
Do not disassemble the charger. There are no user-serviceable parts
in the charger.
While the charger is in use, it becomes warm. This is normal.
Do not place the charger in locations that are extremely hot or cold,
dusty or dirty, very humid, or subject to vibration.
Unplug the battery charger immediately and contact your Intermec
service representative if the status light continues blinking or fails to
light, if any part of the charger appears worn or damaged, or if any
difficulty arises while using the battery charger.
Ordering Power Cords for the Battery Charger
If you have not already ordered an Intermec power cord for your
charger, contact your Intermec sales representative and order one:
Part No.
Voltage
Where Used
586105
100-120 VAC
Canada, Central America, Japan, Korea,
Mexico, Taiwan, and US
586266
220-250 VAC
UK
586267
220-250 VAC
Europe
586276
220-230 VAC
Liechtenstein, Switzerland
586281
220-250 VAC
China, South Pacific
586282
120-250 VAC
Chile, Italy
586283
220-250 VAC
Denmark, Greenland
TRAKKER Antares 4-Pack Battery
Charger Instruction Sheet
The TRAKKER
®
 Antares
 4-pack battery charger (P/N 064667) lets you
simultaneously charge up to four battery packs for the TRAKKER
Antares 2400 series hand-held terminals.
These instructions describe how to install and use the battery charger.
Before using the charger, please read these instructions thoroughly and
retain them for future reference. For help managing battery power, see
your TRAKKER Antares 2400 series terminal user’s manual.
Warning
To prevent fire or electric shock, do not expose the
battery charger to rain or moisture
.
Avertissement
Pour éviter des risques d’incendie ou de choc électrique,
ne pas exposer le chargeur de la batterie à la pluie ou à
l’humidité.
Specifications
Power requirements
100-240V AC, 50/60Hz
Power consumption
26 VA (at 100V), 42 VA (at 240V)
Application
SONY NP-500 series battery pack
(such as NP-520, NP-500, and NP-F530)
Operating temperature
0ºC to 40ºC (32ºF to 104ºF)
Storage information
-20ºC to 60ºC (-4ºF to 140ºF)
Dimensions
Approx. 76 X 112 X 165 mm (3 X 4.4 X 6.5 in.)
Design and specifications are subject
to change without notice.
6001 36th Avenue West
P.O. Box 4280
Everett, WA 98203-9280
© 1998  Intermec 
All Rights Reserved
P/N 064746-002