Intermec 2430 User Guide

Page of 374
Chapter 5—Reader Command Reference 
114 
Trakker Antares 2400 Family System Manual 
 
From Network: 
/.
 
 
Keypad or Menu: Not 
supported 
 
Scan: Not 
supported 
 
Description:  The Scanner Trigger Off command performs the same function as 
releasing the scanner trigger on an external scanner or the Scan button on 
the hand-held terminal keypad. 
 
From Network: 
/%
 
 
Keypad or Menu: Not 
supported 
 
Scan: Not 
supported 
Set Time and Date 
 
Description:  Sets the time and date on the terminal. When the terminal receives the 
time broadcast command from the 9154 or 9161 controller, the command 
sets the clock on the terminal. You can configure the clock with seconds or 
without seconds. 
Use this command only for backward compatibility with the 95XX 
terminal. In the 95XX terminal documentation, this command was called 
Enable Clock. If you do not need backward compatibility, use the Time 
and Date configuration command. For help, see “Time and Date” on page 
255. 
 
From Network: 
/+data
 
Acceptable formats for data to set the time and date are: 
yy/mm/dd:hh:mm:ss 
yy/mm/dd:hh:mm 
hh:mm:ss 
hh:mm 
Year values (yy) from 00 to 95 are interpreted as 2000 through 2095. Year 
values from 96 to 99 are interpreted as 1996 through 1999. 
 
Keypad or Menu: Not 
supported. 
 
Example: 
Set Time and Date to 1:30
 
*/+1/Z30* 
*/+1/Z30* 
 
Note: To use this reader command, you must configure the terminal to 
use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.