To quickly disable or enable the Menu System (Test and Service Mode), 
scan one of these bar codes: 
Disable Menu System 
*$+DC..-.0* 
*$+DC..-.0* 
Enable Menu System 
*$+DC..-.1* 
*$+DC..-.1* 
Using the Override Options 
You can disable or enable reader commands using the Command 
Processing configuration command or the TRAKKER Antares 2400 Menu 
System. To temporarily enable all the reader commands, you can use the 
Enable Override option. You must use the Disable Override option to 
return the terminal to the previous configuration. 
 
Note: If you do not use the Disable Override option, you may not be able 
to disable or enable reader commands. The Enable Override option is the 
only bar code label you can scan to enable reader commands if you have 
disabled all reader commands (DC0). However, you can also enable reader 
commands in the TRAKKER Antares 2400 Menu System. 
 
Bar Codes:  To use the override options, scan one of these bar code labels: 
Enable Override 
Disable Override 
*$+DC3* 
*$+DC2* 
 *$+DC3* 
*$+DC2* 
Configuration Commands Via Serial Port 
 
Terminals:  All Trakker Antares terminals. 
 
Description:  Allows you to control the data the terminal receives through the serial 
port. You can configure this command for the Configurable 
communications protocol. For more information, see the networking 
chapter in your user’s manual.  
You can set this command to execute reader and configuration commands 
received through the serial port or treat all data as data without checking 
for special command syntax. There are three options.