Chapter 6—Configuration Command Reference 
Trakker Antares 2400 Family System Manual 
163 
 
Or:  To disable the configuration commands via serial port for each serial port, 
scan these bar codes: 
COM1 Commands Via 
COM2 Commands Via  
Serial Port Disabled  
Serial Port Disabled 
*$+YT1.0* 
*$+YT2.0* 
*$+YT1.0* $+YT2.0* 
COM3 Commands Via 
COM4 Commands  
Serial Port Disabled 
Via Serial Port Disabled 
*$+YT3.0* 
*$+YT4.0* 
*$+YT3.0* *$+YT4.0* 
 
Or:  To set the configuration commands via serial port to enabled with TMF 
for each serial port, scan these bar codes: 
COM1 Commands Via 
COM2 Commands Via 
Serial Port Enabled With TMF 
Serial Port Enabled With TMF 
*$+YT1.1* 
*$+YT2.1* 
*$+YT1.1* $+YT2.1* 
COM3 Commands Via 
COM4 Commands Via 
Serial Port Enabled With TMF 
Serial Port Enabled With TMF 
*$+YT3.1* 
*$+YT4.1* 
*$+YT3.1* *$+YT4.1* 
Controller Connect Check Receive Timer 
 
Terminals:  2415, 2425, 2435, 2455, 2475, and 2485/6. 
 
Description:  During periods of inactivity on the terminal, the terminal still sends 
messages to the Intermec Gateway or DCS 30X to check the RF or 
Ethernet connection. If no message is received within the time set for the 
Controller Connect Check Receive Timer, the terminal is no longer 
connected to the Intermec Gateway or DCS 30X and the Network 
Connect status light (or the Connect LED or the Connect icon) blinks. 
The timer countdown resets each time a valid message is received. 
Power Management Tip: Intermec strongly recommends that you use the 
optimum setting of 60 seconds. 
 
Syntax: NPdata 
Acceptable values for data are any number from 1 to 3600 seconds (60 
minutes). 
 
Default: 60 
seconds 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Advanced 
Network