Intermec 2430 User Guide

Page of 374
Chapter 6—Configuration Command Reference 
216 
Trakker Antares 2400 Family System Manual 
 
Or:  To set the password to an ASCII character string: 
 
Note: To set this command using the bar code labels from the “Full ASCII 
Bar Code Chart” on page 284, you must configure the terminal to use 
Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 
Scan this bar code: 
  Enter Accumulate Mode / Set Password 
 
*+/$+LT* 
 *+/$+LT* 
Scan a value for data from the “Full ASCII Bar Code Chart” on page 
284. The password can be from 1 to 32 characters. 
Scan this bar code: 
  Exit Accumulate Mode 
 
*-/* 
 *-/* 
PDF417 
 
Terminals:  241X, 242X, and 243X terminals with a PDF417 scanner. 
 
Description:  The PDF417 symbology is a stacked 2D symbology that allows you to 
scan across rows of code. Each row consists of start/stop characters, row 
identifiers, and symbol characters, which consist of four bars and four 
spaces each and contain the actual data. This symbology uses error 
correction symbol characters appended at the end to recover loss of data.   
 
Note: PDF417 is a decoded bar code symbology and requires at least one 
data value in a bar code. Therefore, if the terminal is configured to scan 
decoded bar code symbologies, it cannot scan the Enter reader command, 
which only consists of a Start and Stop character and does not contain any 
data values. 
 
Syntax: CQdata 
Acceptable values for data are: 
0 Disabled 
1 Enabled 
 
Default: Enabled 
 
Menu System:  Main Menu > Configuration Menu > Symbologies Menu