Parity 
 
Terminals:  All Trakker Antares terminals. 
 
Description:  Sets the parity for the serial port. The terminal uses parity for error 
checking in data transmissions. You can configure parity for the Binary 
and Configurable communications protocols. For more information, see 
the networking chapter in your user’s manual. 
 
Syntax: YBn.data 
where n is: 
COM1 serial port 
COM2 serial port (246X and 248X terminals only) 
COM3 serial port (242X terminals only) 
COM4 serial port (242X, 2455, and 248X terminals only) 
Acceptable values for data are: 
0 No 
parity 
1 Even 
parity 
2 Odd 
parity 
 
Default: Even 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Serial 
Port 
 
Bar Codes:  To set the default parity for each serial port, scan these bar codes: 
Even Parity for COM1 
Even Parity for COM2 
*$+YB1.1* 
*$+YB2.1* 
*$+YB1.1* *$+YB2.1* 
Even Parity for COM3 
Even Parity for COM4 
*$+YB3.1* 
*$+YB4.1* 
*$+YB3
.
1* *$+YB4
.
1*