Intermec 2430 User Guide

Page of 374
Chapter 6—Configuration Command Reference 
Trakker Antares 2400 Family System Manual 
227 
COM2 for either RS-232 or RS-422/485 communications. If you are 
using Multi-Drop protocol, you do not need to set this parameter because 
the terminal automatically sets the RS-485 interface. 
 
Syntax: YK2.data 
Acceptable values for data are: 
0 RS-232 
1 RS-422/485 
 
Default: RS-232 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Serial 
Port [COM2] 
 
Bar Codes:  To set the interface for COM2, scan one of these bar codes: 
Enable RS-232 Interface 
Enable RS-422/485 Interface 
*$+YK2.0* 
*$+YK2.1* 
*$+YK2.0* $+YK2
.
1* 
Roaming Flag 
 
Terminals:  2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. 
 
Description:  Determines whether or not the RF terminal can roam between access 
points. All access points are master stations, and each master has a unique 
channel. If you have five access points in one domain, the RF terminal will 
connect to one access point when you turn it on. This access point 
becomes the master station for the RF terminal. When you set the roaming 
flag to “Not Allowed,” the RF terminal will only communicate with the 
master station (access point) to which it first connects. If you allow 
roaming, the RF terminal can communicate with any access point in the 
same domain. 
 
Syntax: RRdata 
Acceptable values for data are: 
0 Allowed 
1 Not 
allowed 
 
Default: Allowed 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Radio 
 
Bar Codes:  Scan one of these bar codes: 
Roaming Allowed 
Roaming Not Allowed 
*$+RR0* 
*$+RR1* 
*$+RR0* *$+RR1*