Intermec 2430 User Guide
Chapter 6—Configuration Command Reference
Trakker Antares 2400 Family System Manual
235
Scanner Trigger
Terminals: All Trakker Antares terminals.
Description: Scanner trigger allows you to set level triggering and either edge or pulse
triggering depending on the type of scanner you are using. There are three
triggering options: level, edge, and pulse.
triggering options: level, edge, and pulse.
Scanner Trigger Options
Option
Description
Level
triggering
triggering
Level triggering is available on terminals using either decoded or
non-decoded scanners. With level triggering, when you activate the
scanner, the laser turns on and stays on until you release the trigger
on the laser scanner.
non-decoded scanners. With level triggering, when you activate the
scanner, the laser turns on and stays on until you release the trigger
on the laser scanner.
Edge
triggering
triggering
Edge triggering is available on terminals using non-decoded scanners.
With edge triggering, when you activate the scanner, the laser turns
on and stays on. When you activate the scanner a second time, the
laser turns off. Simply releasing the button or trigger does not turn
off the laser. If the laser is left on, the scanner timeout turns the laser
off.
With edge triggering, when you activate the scanner, the laser turns
on and stays on. When you activate the scanner a second time, the
laser turns off. Simply releasing the button or trigger does not turn
off the laser. If the laser is left on, the scanner timeout turns the laser
off.
Pulse
triggering
triggering
Pulse triggering is supported on 241X terminals using the integrated
PDF417 scanner or linear imager and on 242X terminals using the
PDF417 scan module. With pulse triggering, when you activate the
scanner, the laser turns on. The laser remains on until the scanner
timeout turns the laser off. If the scanner timeout is set to 0, the laser
turns off after 3 seconds.
PDF417 scanner or linear imager and on 242X terminals using the
PDF417 scan module. With pulse triggering, when you activate the
scanner, the laser turns on. The laser remains on until the scanner
timeout turns the laser off. If the scanner timeout is set to 0, the laser
turns off after 3 seconds.
Note: Earlier versions of PDF417 scanners do not support pulse
triggering. For help upgrading your scanner, contact your local Intermec
service representative.
triggering. For help upgrading your scanner, contact your local Intermec
service representative.
Syntax: SCdata
Acceptable values for data are:
0 Level
triggering
1
Edge or Pulse triggering
Default: Level
triggering
Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner
Bar Codes: Scan one of these bar codes:
Enable Level Triggering
Enable Edge or Pulse Triggering
*$+SC0*
*$+SC1*
*$+SC0* *$+SC1*