Intermec 2430 User Guide

Page of 374
Chapter 6—Configuration Command Reference 
236 
Trakker Antares 2400 Family System Manual 
Security Identification (ID) 
 
Terminals:  2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. 
 
Description:  Defines a password for secured transmission and receipt of data between 
devices in the RF network. To communicate, all access points and RF 
terminals in the subnetwork must have the same security ID.  
 
Note: The Network Activate command must be configured to the RF 
network before you can save any changes to this parameter. 
 
Syntax: RSdata 
Acceptable values for data are up to 20 ASCII characters. 
 
Default:  No characters or blank (Disabled) 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Radio 
The actual security ID does not appear on the screen. The words (ID 
unchanged) indicate that the password has not been changed in the 
current menu session. If you change the security ID, you see the new 
password until you exit the Configuration Menu and update the current 
(runtime) configuration. 
 
Bar Codes:  To disable or set the security ID to no characters, scan this bar code label: 
Disable Security ID 
*$+RS* 
*$+RS* 
 
Or:  To set the security ID to an ASCII character string: 
 
Note: To set this command using the bar code labels from the “Full ASCII 
Bar Code Chart” on page 284, you must configure the terminal to use 
Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 
Scan this bar code: 
 
Enter Accumulate Mode / Set Security ID 
 
*+/$+RS* 
 *+/$+RS* 
Scan a value for data from the “Full ASCII Bar Code Chart” on page 
284. The security ID can be from 1 to 20 characters. 
Scan this bar code: 
 
Exit Accumulate Mode 
 
*-/* 
 *-/*