Intermec 2430 User Guide
nugget
39 AGaramond
Appendix D—Using Default and Optional Applications
Trakker Antares 2400 Family System Manual
309
Or: To set the preamble or postamble using the +., ++, or +% reader
commands:
1
Scan one of these bar code labels:
Enter Accumulate Mode / Set Preamble A
*+/+.*
*+/+.*
Enter Accumulate Mode / Set Preamble B
Enter Accumulate Mode / Set Preamble B
*+/++*
*+/++*
Enter Accumulate Mode / Set Postamble C
Enter Accumulate Mode / Set Postamble C
*+/+%*
*+/+%*
2
Scan a value for data from the “Full ASCII Bar Code Chart” on page
284. The preamble or postamble can be from 1 to 25 characters.
284. The preamble or postamble can be from 1 to 25 characters.
3
Scan this bar code:
Exit Accumulate Mode
*-/*
*-/*
4
Repeat Steps 1 to 3 to set another preamble or postamble.
Full ASCII Mode for Code 39
With the EM9560.BIN application, you can configure Full ASCII mode
for Code 39 using any of these commands:
for Code 39 using any of these commands:
• Code 39 configuration command (CB)
• Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII
Mode reader command (-$)
The last two commands are compatible with the 95XXs. Each command is
described next. For help with the Code 39 configuration command (CB),
see “Code 39” on page 146.
described next. For help with the Code 39 configuration command (CB),
see “Code 39” on page 146.
Note: Use the CB configuration command unless your terminals need to
be compatible with the 95XXs in your data collection network.
be compatible with the 95XXs in your data collection network.
Command: Enter Full ASCII Mode reader command
Description: Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar
code labels by using a two-character encoding scheme to extend the
character set to 128 characters. For a list of ASCII characters, see the “Full
ASCII Table” on page 282.
character set to 128 characters. For a list of ASCII characters, see the “Full
ASCII Table” on page 282.
Syntax: +$