Intermec m90 Reference Guide

Page of 126
Operation Modes
Chapter
3
24
M90 Series Portable Data Entry Unit Reference Manual
When ready, press [ENT SCAN] for the Display Format screen to set a
display format for the M90:
<SYSTEM SETUP>
DISPLAY FORMAT
4*12 (LARGE)
4*12 (LARGE) 4 lines x 12 characters wide (default)
8*16 (SMALL) 8 lines x 16 characters wide
4*20 (M80)
4 lines x 20 characters wide virtual screen, last 4 characters truncated
6*20 (M80)
6 lines x 20 characters wide virtual screen, last 4 characters truncated
The “4*20” and “6*20” formats are M80-compatible. They display four or
six lines with the first 16 characters visible and the last four characters
(positions 17–20) truncated. An M80 program can run without problems
as the system ignores characters found outside the physical screen.
Press " to scroll between formats. When ready, press [ENT SCAN] for
the “Power-On Logo” screen to dictate whether the initial power-on logo
should appear. Press " to toggle between “ENABLE” (default) and
“DISABLE.” When ready, press [ENT SCAN] to return to System Setup.
Press and release [FN], then press " to return to System Setup without
changes.
<SYSTEM SETUP>
POWER-ON LOGO
ENABLE
Supervisor Mode
The M90 has a Supervisor Mode to set up system configurations and
verify computer hardware. Do the following to enter the Supervisor Mode:
1
Turn off the M90. Press and hold ", then simultaneously press [S1]
and [FN]. The M90 powers on with the following screen:
START MENU
1. Supervisor Mode
2. Warm Start
3. Cold Start
4. Cancel