Specifications 
Design and specifications are subject to change without notice. 
Product 
Intermec TZ2410 battery charger 
Electrical requirements 
Input voltage: x 12V; 1,7A 
Application 
Intermec lithium-ion battery pack (P/N 069428, 
P/N 069429, P/N 073929, or P/N 073930) 
Charge cycle 
Current limit: 1.4 Amps maximum 
Float voltage: 4.2V + 50 mV, - 100mV 
Operating 
environment 
Temperature: 0°C to 50°C (32°F to 122°F) 
Humidity: 0 to 95%, non-condensing 
Storage environment 
Temperature: -20°C to 50°C (-4°F to 122°F) 
Humidity: 0 to 95%, non-condensing 
Dimensions 
Approximately 51 x 102 x 178 mm (2 x 4 x 7 in) 
Weight 
Approximately 365.7 g (12.9 oz) 
Ordering Power Cords for the Battery Charger 
The AC power cord is ordered separately. If you need to order an 
Intermec power cord, contact your Intermec sales representative. 
Country 
Part Number 
North and Central America 
586105 
Europe 
586267 
Denmark and Greenland 
586283 
Italy and Chile 
586282 
Liechtenstein and Switzerland 
586276 
United Kingdom 
586266 
South Pacific 
586281 
China 
071918 
4-Pack Battery Charger (TZ2410) Instructions 
*069549-002* 
P/N 069549-002 
6001 36th Avenue West
Everett, WA  98203
U.S.A.
www.intermec.com
© 2004  Intermec Technologies Corp. 
All Rights Reserved
 
 
4-Pack Battery Charger (TZ2410) Instructions 
Use the Trakker Antares
®
 TZ2410 battery charger to simultaneously 
charge up to four battery packs for the Trakker Antares 241X 
Handheld Terminals. 
Before using the charger, please read this guide and keep it for future 
reference. For help managing battery power, see your Trakker Antares 
241X Handheld Terminal User’s Manual 
(P/N 069538). 
Choosing a Location for the Battery Charger 
 
To prevent fire or electric shock, do not expose the 
battery charger to rain or moisture. 
Attention Danger: Pour éviter des risques d’incendie ou 
de choc électrique, ne pas exposer le chargeur de la 
batterie à la pluie ou à l’humidité. 
Use these guidelines to choose a location for the charger: 
•  Locate a flat, stable, and clean surface that is within 1.5 m (5 ft) of 
an electrical source (AC outlet). 
•  Provide access to the power supply jack on the battery charger and 
to the battery charger itself so you can easily load and unload 
batteries. 
Connecting the Power Supply 
Before you can use the battery charger, you will need to have an 
autoranging external power supply (P/N 065236 or P/N 073941). 
Plug the external power supply connector into the power supply jack 
on the battery charger and then connect the AC power cord (ordered 
separately) to the power supply and to an AC outlet. 
Charging a Battery Pack 
You can charge up to four Intermec-labeled lithium-ion battery packs 
simultaneously, using any slot. The charging times indicate the