Intermec 2480 Installation Instruction

Page of 2
8. Connect the 9-pin RS-232 connector from a serial device to the COM4 adapter cable on the
back of the terminal.
9. Configure COM4. For help, see the TRAKKER Antares 248X Stationary Terminal User’s
Manual (Part No. 066960).
Pin Assignments
The next illustrations show the pin assignments for the 9-pin connector (host connection) and
the 10-pin connector (terminal connection) on the adapter cable.
9-Pin Connector Pin Assignments
Not connected - 6
Request to send (RTS) - 7
Clear to send (CTS) - 8
Not connected - 9
1 - Not connected
2 - Received data (RXD)
3 - Transmit data (TXD)
4 - Data terminal ready (DTR)
5 - Ground (GND)
248XIC4C.003
10-Pin Connector Pin Assignments
1 - Received data (RXD)
3 - Transmit data (TXD)
5 - Data terminal ready (DTR)
7 - Ground (GND)
9 - Not connected
Request to send (RTS) - 2
Clear to send (CTS) - 4
 Not connected - 6
Not connected - 8
Not connected - 10
248XIC4C.003
6001 36th Avenue West
P.O. Box 4280
Everett, WA 98203-9280
© 1998  Intermec 
All Rights Reserved
P/N 068251-002