Intermec 1555 Reference Guide

Page of 178
Interactive Programming Mode
4-5
4
rate by the remote control interface, the new baud rate is applied after you restart the 
product. The default baud rate for the 1555 is 19200 bps.
Default RS-232 Parameters
The following parameters are factory default settings for the serial interface:  19200 
bauds, 8 bits, no parity, 2 stop bits.
Hardware Protocol
This interface can be configured to operate with or without the request to send/clear to 
send (RTS/CTS) hardware protocol.
The product can send an RTS signal to the host or product and will wait for a CTS 
from the host or product before sending the data (character by character).
The RTS/CTS protocol can be enabled or disabled. The factory default is disabled.
Point-to-Point Protocol
This section defines the interface command structure, or PPP, which is used to 
communicate between Intermec products.
Frame Format
The frame format is used with Intermec data capture products to communicate with
PC applications (e.g., EasySet or customer applications).
submodules communicating with the main board of the product.
The frame format is defined as follows:
< STX > < TYPE > <CMD/RESP> < [PARM/DATA] > < FRAME_MANAGEMENT > < CHK > < ETX >
Table 4-3 lists the frame format components.
Table 4-3  Frame Format Components
Item
Length
Description
<STX>
1 byte
Delimiter, value of 0x7F
<TYPE>
1 byte
Frame command type
<CMD/RESP> <[PARM/DATA]>
[0 - n] bytes
Setup command or response code, optional 
parameters or data