Intermec 1470 User Guide

Page of 316
1470/1471 Imager User’s Manual
3-30
Or scan one of the following bar codes. The default setting is marked with an asterisk
(*).
Off
*
On
Scan Stand Bar Code
When an imager is in Scan Stand mode, the LED shines at the Scan Stand bar code,
which is on the base of the stand. The Scan Stand bar code tells the imager to remain
idle. When a bar code is presented that completely covers the Scan Stand bar code but is
not the Scan Stand bar code, the imager turns on and decodes it.
Scan Stand Bar Code
Scan Stand LED Intensity
Scan Stand LED Intensity sets the idle LED intensity when the imager is in Scan Stand
mode. When an imager is in Scan Stand mode, the LED shines at the bar code on the
base of the stand, which tells it to remain idle. When a different code is presented, the
imager is triggered to read the new code. If the imager has difficulty going back to
reading the Scan Stand’s fixed code (for instance, in a low lighting situation), you may
want to adjust the Scan Stand LED Intensity. A two-digit number between 15 and 75
must be input after the Scan Stand LED Intensity code is scanned. A 15 corresponds to
the lowest intensity level, and a 75 corresponds to the highest intensity level. The
default setting is 15.
Note that when the imager is triggered to read a code, the imager uses the LED power
level specified through “LED Power Level” earlier in this chapter.