Label Length Format
The following two sections explain how to set the Codabar Label 
Length Format to either the Variable Length or Fixed Length 
Format.
Variable Length Format
You can set the Codabar symbology to Variable Length Format. 
To set the Codabar symbology to Variable Length Format
1
Identify the minimum length setting you want to make. The 
selectable range is 03 to 50 characters. 
2
Scan the SET bar code.
3
Scan the Enable Variable Length Format bar code.
4
Scan the Set Minimum Label bar code.
5
Using the Digits bar codes on page 102, scan the digits to set 
the minimum label length you identified in Step 1.
Gap Check
Enable
 ---------
Disable  
---------
END------------------------------------ 
Note: For this symbology, the scanner decodes up to 50 
characters, but the actual length read varies depending upon 
the interface type, bar code physical size, and print quality.