Bosch ngp732uc Installation Instruction

Page of 28
English 4
Countertop Requirements
Figure 2 - Cutout Dimensions 
Gas Requirements - 
Supply Pressure
Natural Gas - 6 inches water column (14.9 Millibars) minimum.
Propane Gas -11 inches water column (27.4 Millibars) minimum.
Propane Gas Installation
(NGT Models only)
NOTE: NGP models cannot be converted for propane use.
The propane gas tank must be equipped with its own high pressure regulator in 
addition to the pressure regulator supplied with this unit. The cooktop is shipped 
from the factory for use with natural gas. For use with LP,  a conversion kit is 
required and must be purchased separately. Contact BSH or your retailer to obtain 
kit # NEZ1065.  A qualified technician or installer must do the conversion.
Leak testing of the appliance shall be conducted according to manufacturerís 
instructions.
4” (101.6mm) Below Countertop
21” (533.4 mm) cooktop depth
Side Wall 
7-3/8”(187.8 mm)
Min. to Counter
1/8” (3.5mm)
6” (152.4mm) Min
Combustible Wall 
Right Side Wall 
3” (76.2 mm) Min. to 
1-3/4” (44.5 mm) Min. to 
to Left Side Wall 
Min Clearance 
from Cooktop to  
2 1/4” (57.2mm)
Start of Radius  
Left Side Wall 
4 3/8”  (111.6mm)
 to Back Wall 
3” (76.2 mm) Min. 
Min. to Right 
Min. to 
Front 
 
Table 1: Cutout Dimensions
Fig. 2
30” Models
36” Models
A - Cutout
19-1/8” to 19-7/8”
(486.1mm) to 
(505.6mm)
19-1/8 to 19-7/8”
(486.1mm) to 
(505.6mm)
B - Cutout
28-5/8” to 29-3/8”
(727.2mm) to 
(746.6mm)
34-5/8” to 35-5/8”
(879.6mm) to (899mm)
C - Corner
30” (762mm)
36” (914.4mm)
D - Overall
31” (787.4mm)
37” (939.8mm)