American Dynamics ad1641m-2 Operating Guide

Page of 36
SETUP
Camera Number Setup
For 1641M and 1641S models:
A 10-position DIP switch labeled “CAMERA ID” is used to
associate a specific camera number with the Receiver for
individual control by the Matrix Switching System.  This
switch, labeled S10 on the main PCB, is located on the side
panel of the 1641 Receiver, near the Pan/Tilt/Lens cable and
the LENS ADJ control (see Figure 1, page 1).  Set this DIP
switch to the camera number assigned by the Matrix Switching
System.  See the tables in the Appendix for the proper DIP
switch settings for system camera numbers.
Lens Voltage Adjust
The 1641 can be adjusted for a range of camera Lens servo
voltages.  The lens output voltage can be varied from 7 to 12
Volts DC with a potentiometer, labeled “LENS ADJ”.  This
control is located on the side panel of the 1641, near the
CAMERA ID switches (see Figure 1, page 1).
Receiver Configuration Setup
The 1641 Receiver must be configured for the type of
auxiliaries used, the preset capabilities, and for the type of
control interface.  An internal DIP switch located on the main
1641 PCB, labeled S7, is provided to set the Receiver
configuration (Figure 3).  See Figures 4, 5, and 6, on pages 6,
7, and 8, for the location of DIP switch S7 on the main PCB.
Table 2 below identifies the Receiver setup functions for each
switch position of this DIP switch (see Figure 3).
Table 2 - DIP Switch S7 Setup
DIP Switch Position
Function
1 & 2
Pan/Tilt Setup
3
Code Control 
4
AUX 1 Configuration
5
AUX 2 Configuration 
6
Autopan Timer/Timeout
7 & 8
Not used
The following explain each of the DIP switch S7 positions.
The factory default settings are shown in bold type.
Pan/Tilt Setup -  Switch Positions 1 & 2
1
2
ON ON
No 
Presets
OFF 
ON
Non-360 degree potentiometers
ON 
OFF
360 degree ramp potentiometers
OFF 
OFF
360 degree SIN/COS potentiometers
Note: If the Pan/Tilt Preset switches or Preposition wiring
(page 13) are changed, the unit must be power-reset, see
page 14.
Control Type -  Switch Position 3
ON -
AD Manchester Control Code (1641M series), 
or Local Test Mode
OFF -   RS-232 (1641S, series)
Note: If RS-232 Code is used (1641S), the RS-232 setup
switches must also be set, see page 5.
AUX 1 Configuration -  Switch Position 4
ON -
Momentary
OFF -   Latching
AUX 2 Configuration -  Switch Position 5
ON -
Momentary
OFF -  Latching
Autopan Timer/Timeout -  Switch Position 6
ON -
Autopan for 30 minutes then stops
OFF -   Autopan continuously, until manually stopped
Positions 7 & 8 - not used
4
SETUP
-  CAUTION  -
The following internal modifications will expose
hazardous-voltage components and allow access to
dangerous electric shock potentials.  These modifications
should be made only by  qualified service personnel.
Not used
Not used
Pan/Tilt Setup
Code Control
AUX 1 Config
AUX 2 Config
Autopan Timer/Timeout
1
2
3
4
5
6
7
8
X
X
ON
OFF
Figure 3 -  DIP Switch S7 switch positions