Silver King skdd2 User Guide

Page of 6
 
 
 
Electrical Connections             
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power.  The 
specifications on the data plate supersede any future discussion.   
 
The standard back bar cooler is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly 
grounded  electrical  receptacle.    The  power  cord  comes  with  a  3  prong  plug  for  grounding  purposes.    Any  attempt  to  cut  off  the 
grounding spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and 
could result in serious injury. 
 
The circuit must be protected with a 15 or 20 ampere fuse or breaker.  The unit must be isolated on a circuit and not plugged into an 
extension cord. 
 
OPERATION
 
Initial Start-Up 
After satisfying the installation requirements, the back bar cooler is ready to start.  The Compressor will start when the power cord is 
connected to the required power source.  If the Compressor does not start when the unit is initially plugged in, check to make sure 
that the Temperature Control is not in the "off" position.  Allow the unit to run for two hours before loading it with product.  When 
loading the unit with product, take care not to block the air flow in the cabinet as this would affect the units performance. 
 
Temperature Control 
The Temperature Control is located on the left end of the back wall of the cabinet interior and is factory set to maintain an average 
cabinet temperature of approximately 36 to 40 Deg F.  To obtain colder temperatures turn the Temperature Control stem clockwise 
and vice versa.  Allow the unit a minimum of one hour to respond to a control setting adjustment. 
 
Defrost 
Your  Silver  King  bottle  cooler  is  an  automatic  defrost  unit  and  no  additional  plumbing  is  required.    Automatic  defrosting  is 
accomplished when frost buildup on the Evaporator Coil is cleared during Compressor "off" cycles.  Defrost water is collected in a 
pan located in the compressor compartment where it is evaporated into the room air.  It is important that the unit be installed level to 
allow proper drainage of the defrost water. 
 
Light 
The on / off switch for the interior light is located on evaporator panel. 
 
 
MAINTENANCE 
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 
the appliance. 
 
Cabinet Surfaces 
The interior and exterior surfaces should be cleaned periodically with a solution of warm water and mild soap, rinsed and wiped dry 
with  a  soft  cloth.    A  good  stainless  steel  cleaner  can  also  be  used  on  the  stainless  steel  surfaces.    Should  a  surface  become 
stained, do not attempt to clean with an abrasive cleanser or scouring pad.  Use a soft cleanser and rub with the grain of the metal 
to avoid scratching the surface.  Do not use chlorinated cleaners.  Always rinse well and dry after cleaning.  To help remove odors, 
the interior surfaces of the unit should be periodically cleaned with a solution of baking soda and warm water.   
 
Condenser 
Periodically the Condenser must be cleared of dust.  The Condenser is located behind the front grill on the cabinet.  To clean the 
Condenser simply remove the front grill and brush or vacuum the exposed condenser fins.  This will need to be done regularly to 
maintain proper performance and increase the life of the unit. 
 
Drain Pan 
The  Drain  Pan  is  located  under  the  front  grill  and  can  be  removed  by  pulling  is  out  the  front  of  the  unit.    Depending  on  local 
conditions the Drain Pan may need to be periodically emptied and cleaned. 
 
Door Gasket 
The Door Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure 
maximum cabinet performance and life. 
MODEL 
SERIAL NO. 
DATE INSTALLED