Adjusting the Fan Speed
1. Automatic 
Simply set the FAN SPEED selector to the           position.
A microcomputer in the air conditioner automatically controls  the fan speed when the        mode is selected. When the 
air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is 
detected by the microcomputer which then automatically switches the fan speed to the most suitable level.
Cooling mode:
                        When difference between room                               FAN SPEED
                      temperature and set temperature is
                                          RT ≥ T+3℃                             High
                             T+3℃ > RT ≥ T+1℃                           Medium
                                          RT
                                                    Low
Mild drying  mode:
                       When difference between room                                FAN  SPEED 
                     temperature and set temperature is
                                         RT ≥ T+5℃                                                   High
                            T+5℃ > RT ≥ T+3℃                                                 Medium
                                         RT
                                      Low
 < T+1℃ 
≤ T+3℃ 
2. Manual
If you want to adjust  fan speed manually during operation, just set the FAN SPEED selector as desired.
High:
Medium:
Low:
The above table assumes that the sensor on the remote control  is being used. If the sensor in 
the indoor unit is being used (the      indicator is on), actual operation may differ slightly 
from the operation described in table.
NOTE