Hisense kf-2302gwe 用户指南
Operation Guide
10
Adjusting the Fan Speed
1. Automatic
Simply set the FAN SPEED selector to the position.
A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected. When the
air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is
detected by the microcomputer which then automatically switches the fan speed to the most suitable level.
Simply set the FAN SPEED selector to the position.
A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected. When the
air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is
detected by the microcomputer which then automatically switches the fan speed to the most suitable level.
Cooling mode:
When difference between room FAN SPEED
temperature and set temperature is
RT ≥ T+3℃ High
T+3℃ > RT ≥ T+1℃ Medium
RT
temperature and set temperature is
RT ≥ T+3℃ High
T+3℃ > RT ≥ T+1℃ Medium
RT
Low
Mild drying mode:
When difference between room FAN SPEED
temperature and set temperature is
RT ≥ T+5℃ High
T+5℃ > RT ≥ T+3℃ Medium
RT
temperature and set temperature is
RT ≥ T+5℃ High
T+5℃ > RT ≥ T+3℃ Medium
RT
Low
< T+1℃
≤ T+3℃
2. Manual
If you want to adjust fan speed manually during operation, just set the FAN SPEED selector as desired.
High:
Medium:
Low:
The above table assumes that the sensor on the remote control is being used. If the sensor in
the indoor unit is being used (the indicator is on), actual operation may differ slightly
from the operation described in table.
the indoor unit is being used (the indicator is on), actual operation may differ slightly
from the operation described in table.
NOTE