Appendix: Installation
1. SUMMARY
1.1 Notice
This operation manual has explicit information for 
installation  and  maintenance  in  most  conditions. 
Contact the local distributor or after-sales service 
for further information.
1) Wiring notice
   Only qualified professionals should carry out wiring 
of the appliance.
    Disconnect  the  power  supply  before  completion  of 
wiring, piping or checking the appliance.
    Voltages generated by the appliance is fatal.
Read the electrical schematic diagram and explanation 
before installation. Improper installation and earth 
connection may result in fatal injury.
    Connect the earth as required by local regulations.
  Tightly fasten all the wiring connections to prevent 
overheating or fire.
   Special power, switches and sockets are required for 
the power supply of the appliance.
    Electric  meter  capacity  must  be  larger  than  or 
equivalent to 10A.
Remark per EMC Directive 89/336/EEC
To prevent flicker impression during the start of the 
compressor  (Technical  Process)  and  the  adversely 
nd
influence  caused  by  the  2   harmonics  of  compressor 
following installation conditions do apply
1. The power connection for   the air conditioner has to 
be  done  at  the  main  power  distribution.  This 
distribution has to be of a low impedance is reached at 
32A fusing point.
2. No other equipment has to be connected to this power 
line.
3. For the detailed installation acceptance please refer 
to  your  contract  with  the  power  supplier,  if 
restrictions  do  apply  for  products  like  washing 
machines, air conditioners or electrical ovens.
4.  For  the  details  of  the  power  of  air  conditioner, 
please refer to the rating plate of the product.
5. For any question contact your local dealer.
2). Transport
    Carefully move the outdoor unit.
3). Installation
----When the appliance is mounted to the ceiling or the 
wall,
     Make sure that the ceiling or the wall is strong 
enough for the appliance.
   Make a wood or metal frame to support the appliance if 
necessary.
----When the appliance is mounted in a room,
     Properly insulate the outdoor unit, and make sure 
there is no moisture on the appliance or on the floor.
----When the appliance is installed on a damp or uneven 
area,
   Make a flat concrete base and place the base under the 
outdoor unit.
----When the appliance is installed in an area of strong 
winds.
    Using firm bolts and metal frames to fix the properly 
covered outdoor unit.
----When the appliance (Model Heat Pump) is installed in 
an area of heavy snow.
   The outdoor unit must be installed in a position above 
the snow accumulation.
4). Connection
    Use the shortest tubes possible
    Using a flaring method
   Smear some refrigeration oil between the flared surface 
and the connected tube.
   Fasten the nuts with a torque wrench to prevent leakage of 
refrigerant.
    Check for leakage before trial operation.
5). Maintenance
    Disconnect   the   power     before    checking    the    
electrical 
     components and the circuits.
    Avoid contact with the moving parts of the appliance.
     Clear the site and make sure there is no installation 
debris left in the appliance.
6). Other
    Keep the room well ventilated during installation.
1.2 Installing instruction
Read the operation manual before installation and keep this 
manual in a safe place.
1)Tools
1. Screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Steel ruler
5. Spirit level
6. Hammer
7. Percussion drill
8. Tube cutter
9. Pipe flarer
10. Pipe bender
11. Adjustable spanner
2)  Attachment
     (see the packing list)
3) Parts Package
Copper tubes, components and insulation materials for the 
outdoor unit.
4) Type of the copper tube and insulation materials
1.  Table  1  indicates  that  tubes  should  be  cut  with  an 
additional length of 30cm-40cm, to reduce the vibration from 
the outdoor unit.
 
  
                         Narrow tube
                         
ITEM
Wide tube
       Outside Diameter       Thickness      Outside Diameter   
Thickness
 KF-2302GWE
                
6.35mm
        0.8mm     
9.52mm
      0.8mm
2.  The  insulation  materials  for  the  copper  tubes  should 
conform to the required length and the wall thickness should 
not be less than 8mm.
3. Insulated copper wires should be used for wiring and the 
specification should depend on the length.
5) Additional materials for installation
1. white tape
2. nails or clips (as required)
3. putty
4. refrigeration oil
5. clips for fixing refrigerant tubes
21