CAUTION
   
Appendix: Installation
3. INSTALLATION OF INDOOR UNIT
3.1 Take off the back cover
1) Release the screw as shown by Figure 6.
2) Take off the back cover.
3.2Drilling
1) Locate the back cover of the indoor unit on the wall, 
and determine the desired place with a spirit level and 
a ruler. Before drilling, do not fix the back cover 
onto the wall.
2) According to direction of the tube ,drilling for tubes 
according  to  the  location  of  the  appliance.  It  is 
recommended that the rear right be used for wiring and 
drilling.
3)  Drill a 65mm hole in the wall (Figure 7), make sure the 
Indoor         Outdoor
Before drilling, make sure that 
there  is  no  electric  cable  or 
pipe in the area of the wall where 
the hole is to be drilled.
3.3 Installation of the back cover
1)  check  with  a  spirit  level  that  the  back  cover  is 
installed horizontally. (Figure 8)
2) fix the back cover to the wall with the screws provided. 
(Figure 9). Make sure that the back cover is firmly 
fixed to he wall.
3.4 Install the indoor unit
1)  Thread  the  cable  through  the  hole  in  the  wall,  an 
additional  13cm  of  slack  power  cable  should  remain 
inside the room. (Figure 10)
23
Figure 7
Figure 8
13cm
Lining cover
Back cover
Electrical cable
Figure 10
2) 
3) Adjust the position of the indoor unit, fixing it 
firmly onto the back cover(figure 12). 
Bind  the  connection  cable,  drainage  hose  and 
refrigerant tube together tightly with white adhesive 
tape; bend the refrigerant tube and make them through 
hole of the wall smoothly(figure 11).
Lining cover
Back cover
Refrigerant tube
Connection cable
Drainage hose
Figure 11
Figure 12
Figure 9
Figure 6