Hisense kf-34gwe User Guide

Page of 28
   
Appendix: Installation
(3)Any p ar t o f th e d ra i npi pe sho uld be below the outlet of the 
indoor  un it  and  t h e  joints  should  be  wrapped  with  wat erpr oof 
adhesive tape to prevent leakage of condensed water.
(4)Bind  the  t u be s ,  wires  and  the  dr ain pipe  tightly  wi th 
binding tape, with the drainpipe under the wires.
(5)Press  d ow n  the  c l amp ing  p lat e  of  t he  tubes  and  f ix  the 
bound wires. 
Install the indoor unit
(1)Pull t he bound wi r es out t hro ugh the wall hole and put t he 
indoor  wires  together  with  the  indoor  unit  at  the 
corresponding place of the wall plate.
(2)Hook  t h e  indoor  un i t  o nto  the  r eta ini ng  claws  on  the  wall 
plate a n d move t h e u nit body sli ght ly to make sure that i t i s 
firm.
4. Installation of the outdoor unit
Mount the outdoor unit
A. Mount the outdoor unit in the selected place.
B. If t he o ut do o r unit i s t o be mounted on the wall, the wall 
and  the  installation  bracket  should  have  suffi cien t 
intensity to bear the weight of the outdoor unit.
(1)Place the outdoor unit carefully onto the bracket.
(2)Fix  t he  un it  onto  t he  bracket  w ith  four  bottom  bolts.  The 
bolts s h o ul d h ave a nti-vibration p ad s t o p revent f all ing d own 
of the unit from vibration.
Connect the tubes of the outdoor unit
A. Electric wires
(1)Remove  the  wire  cov er  o f  t he  outdoor  unit  with  a 
screwdriver.
(2)Remove the wire clip.
(3)Connect  the  w ir e s  to  th e  c orr esp ond ing  terminals  o n  the 
terminal panel.
(4)Tighten all the screws to ensure good connection.
(5)Put  the  wires  in t o  pl ace  wi th  a  clip  and  replace  t he  wire 
cover.
B. Tubes
The  connection  of  t he  ou tdoo r  tube s  is  the  same  as  steps  (1 ) 
and (2) of the indoor unit.
Ca ut i on :  A ll  t he  "  Y  "  -s hap ed  terminals  should  be 
pl u gg e d  into  t he  li ne  bank  and  the  grounding  loo p 
t e rm in a l sh ou ld b e conn ect ed fu lly . 
C au t io n :  N e ve r  pu t  extra  wires  into  the  wir e 
c om p ar tm e nt  to  a voi d  d ama ge  from  eddying  flo w 
Wire cover
Wire outlet
Tubes
Drainpipe
Tube clamping plate
Wires
Tubes
Drainpipe
Wall plate
Tubes
Wires
Drainpipe
Tube clamping plate
23