3com 4800G Installation Instruction

Page of 82
14
C
HAPTER
 1: P
RODUCT
 O
VERVIEW
Rear Panel
Figure 9   Rear panel of the Switch 4800G PWR 24-Port
Power Supply System
The Switch 4800G PWR 24-Port can adopt AC power input, or DC power input, or 
both to provide backup.
AC power input
Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Rated voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Only the RPS recommended by 3Com can be used for the Switch 4800G PWR 
24-Port. The -48 VDC power supply in the equipment room cannot be used 
directly. Otherwise, the device may be damaged.
DC power input
Rated voltage range: -52 VDC to -55 VDC
Cooling System
The Switch 4800G PWR 24-Port is equipped with six fans for heat dissipation.
LEDs
For descriptions about LEDs, see Table 5. You can switch the Mode LED display 
mode between speed, duplex, and PoE by pressing the Mode button on the panel.
(7) LED for extended module slot 1 
(8) LED for extended module slot 2 
(9) Mode LED 
(10) Mode button
(1) RPS port 
(2) AC power socket 
(3) Grounding screw 
(4) Extended interface module slot 1 
(5) Extended module slot 2 
(1)
(2)
(3)
(4)
(5)
(1)
(2)
(3)
(4)
(5)
Table 5   Descriptions of the LEDs on the front panel of Switch 4800G PWR 24-Port
LED Mark 
Status 
Description 
Mode LED 
Mode  Speed 
Solid green
Rate of the port 
Duplex  Solid yellow
Duplex mode of the port 
PoE 
Flashing green (1 Hz)
PoE mode of the port 
Power LED 
PWR 
Solid green
The switch is started normally. 
Flashing green (1 Hz)
The system is running a power-on self-test 
(POST). 
Solid red
The system fails the POST or a power 
failure occurs. 
Flashing yellow (1 Hz)
Some ports fail a POST or a port failure 
occurs. 
OFF
The power is disconnected.