3com 4005 Installation Instruction

Page of 77
12
C
HAPTER
 2: O
VERVIEW
 
OF
 
THE
 S
WITCH
4005
Minimum Requirements
for Normal Operation
The following minimum components are required for normal operation of the 
Switch 4005:
Two fan trays (four fans total)
One 300 Watt AC power supply
One Switch Fabric Management Module (SFMM) operating with system 
software
The number and type of interface modules that are appropriate for your 
network connectivity needs
Blank faceplates that cover all empty module slots and the second power 
supply bay (if a second power supply is not installed).
Module Slots in the
Chassis
You insert modules vertically into the chassis slots so that the slot number shows 
through a hole in the module faceplate. As shown in Figure 1, the slots for 
interface modules are numbered from left to right, starting with number 1 and 
continuing to 12. The two center slots are numbered M1 and M2 because they 
exist solely to contain Switch Fabric Management Modules (SFMMs). An SFMM 
can be placed in either of these slots.
Figure 1   Front View of a Switch 4005 Chassis Without Interface Modules Installed
Management
module slots
Interface
module slots
Interface
module slots