3com 4005 Installation Instruction

Page of 77
56
C
HAPTER
 7: S
WITCH
 F
ABRIC
 M
ANAGEMENT
 M
ODULES
 
AND
 I
NTERFACE
 M
ODULES
Table 13 lists and explains the status LEDs on Gigabit Ethernet Interface Modules 
and explains their modes. 
Table 13   LED Indicators on Gigabit Ethernet Interface Modules
LED
State or Color
Definition
Diag 
(Diagnostics)
Green
Power is on (normal operation).
Flashing Green
Diagnostics is in progress.
Off
After initial insertion or module reset, the LED 
remains unlit for approximately 3 seconds. At other 
times, an unlit LED indicates diagnostic failure.
Release
Amber
Module is ready for removal.
Flashing Amber
System is preparing for module removal.
Off
Module is operating in its normal state.
Link
Amber
Port is operating at 10 Mbps
1
.
Green
Port is operating at 100 Mbps
1
.
Flashing Green
Port is operating at 1000 Mbps.
Flashing Amber
Port is set to disabled.
Off
Cable is not connected or link is down.
Mode
2
If this LED is Amber 
and FC LED on SFMM 
is Green 
Flow control is enabled.
If this LED is Off and 
FC LED on SFMM is 
Green
Flow control is disabled.
If this LED is Amber 
and FDX LED on 
SFMM is Green
Port is operating at full duplex.
If this LED is Off and 
FDX LED on SFMM is 
Green
Port is operating at half duplex
3
.
If this LED is Amber 
and Act LED on 
SFMM is Green
Port is receiving or transmitting packets.
If this LED is Off and 
Act LED on SFMM is 
Green
Port is not active.
1
 10 Mbps and 100 Mbps operation are possible with the 1000BASE-T module only (not with 
GBIC or 1000BASE-SX modules). 
2
 Use the Mode button on the Switch Fabric Management Module (SFMM) to select the 
display mode, which applies to all interface modules. To determine the mode that is selected 
when you view a Port Mode LED on an interface module, look at the Port Mode LED on the 
SFMM.
3
 Half duplex transmission is possible with the GBIC and 1000BASE-T modules only (not with 
the 1000BASE-SX module).