3com 8807 Reference Guide
890
C
HAPTER
51: P
O
E PSU S
UPERVISION
C
OMMANDS
Parameter
None
Description
Use the display poe-power alarm command to display detailed alarm
information about the PoE PSUs.
information about the PoE PSUs.
Example
# Display detailed alarm information about the PoE PSUs.
<SW8800> display poe-power alarm
PSU alarm detail, PSU number : 2
PSU 1 alarm : NORMAL
PSU 2 alarm : NOTLINK Controller/Rectifier communication Fail
/Rectifier not in present
display poe-power
dc-output state
Syntax
display poe-power dc-output state
View
Any view
Parameter
None
Description
Use the display poe-power dc-output state command to display the current
DC output state of the PoE PSUs.
DC output state of the PoE PSUs.
Example
# Display the current DC output state.
<SW8800> display poe-power dc-output state
DC Output State : Normal
Table 121 Description on the fields of the display poe-power alarm command
Field
Description
NORMAL
Normal
NOTLINK
The PSU is disconnected. That is, the controller was able to communicate with
the PSU; but it cannot now. Power-cycling the unit or re-inserting a new PSU
can resolve this problem.
the PSU; but it cannot now. Power-cycling the unit or re-inserting a new PSU
can resolve this problem.
INERROR
The PSU input is in trouble. Restoring the AC input can resolve this problem.
OUTERROR
The PSU output is in trouble, the PSU cannot output normal DC voltage.
HIGHVOL
The PSU is over-voltage. The PSU is shut down because the output voltage is
too high.
too high.
HIGHTEP
It is overheated in the PSU.
FANERROR
The PSU fan is in trouble.
CLOSE
The PSU is shut down remotely.
CURLIMIT
The PSU is current limited.