display rmon alarm
Syntax
display rmon alarm [ alarm-table-entry ]
View
Any view
Parameter
alarm-table-entry: Alarm table entry index.
Description
Use the display rmon alarm command to view RMON alarm information.
Related command: rmon alarm.
Example
# Display the RMON alarm information.
<SW8800> display rmon alarm
 
Alarm table 1 owned by monitor is VALID.
 
  Samples type          : delta
 
  Variable formula      : 1.3.6.1.2.1.16.1.1.1.3.1<etherStatsDropEvents.1>
 
  Description           : Ethernet5/1/1
 
  Sampling interval     : 10(sec)
 
  Rising threshold      : 10(linked with event 1)
 
  Falling threshold     : 2(linked with event 1)
 
  When startup enables  : risingOrFallingAlarm
 
  Latest value          : 0 
Table 129   Description on the fields of the display rmon alarm command
Field 
Description 
Alarm table 1 
Index 1 in alarm table 
monitor 
Owner 
VALID 
The alarm entry corresponding to this index is valid. 
Samples type 
Type of sampling 
Variable formula 
Variable parameters 
Description 
Description information 
Sampling interval 
Time interval for sampling 
Rising threshold is 1000 
The rising threshold is 1000. 
Falling threshold is 100 