Справочное Руководство для 3com 8807
54
RMON C
ONFIGURATION
C
OMMANDS
RMON Configuration
Commands
Commands
display rmon alarm
Syntax
display rmon alarm [ alarm-table-entry ]
View
Any view
Parameter
alarm-table-entry: Alarm table entry index.
Description
Use the display rmon alarm command to view RMON alarm information.
Related command: rmon alarm.
Example
# Display the RMON alarm information.
<SW8800> display rmon alarm
Alarm table 1 owned by monitor is VALID.
Samples type : delta
Variable formula : 1.3.6.1.2.1.16.1.1.1.3.1<etherStatsDropEvents.1>
Description : Ethernet5/1/1
Sampling interval : 10(sec)
Rising threshold : 10(linked with event 1)
Falling threshold : 2(linked with event 1)
When startup enables : risingOrFallingAlarm
Latest value : 0
Table 129 Description on the fields of the display rmon alarm command
Field
Description
Alarm table 1
Index 1 in alarm table
monitor
Owner
VALID
The alarm entry corresponding to this index is valid.
Samples type
Type of sampling
Variable formula
Variable parameters
Description
Description information
Sampling interval
Time interval for sampling
Rising threshold is 1000
The rising threshold is 1000.
Falling threshold is 100
The falling threshold is 100.