Xerox 128 Service Manual

Page of 174
3 - 4 0
DocuTech 128/155/180 HighLight Color Operator Guide
Routine maintenance
Clearing or cleaning the finisher sensors
NOTE:   Production publisher configuration only
Clearing the finisher sensors should be performed only when 
directed by a Customer Support Center Representative.
NOTE:  The finisher sensors are located under the processor top 
cover, under the finisher top cover, and behind the finisher and 
bindexer doors. 
Use the following procedure to clear any obstructions from the 
finisher sensors.
1. Fold a sheet of 8.5 x 11 inch (216 x 279 mm) paper, as shown 
in figure 3-36.
Figure 3-36  Folding the paper
2. Use the folded sheet of paper to clear any obstructions in the 
following sensor areas.
Clearing the Q1201 sensor
NOTE:   Production publisher configuration only
Clearing the Q1201 sensor should be performed only when 
directed by a Customer Support Center Representative.
1. Open the processor top cover.
NOTE:  The Q1201 sensor is located under the processor top 
cover on the right side.
2. Locate the Q1201 sensor, as shown in figure 3-37