Large, uneven and repeating 
streaks appear on the page.
An internal belt on the imaging unit is 
slipping.
Replace the imaging unit.
One vertical, dark and even 
fine line appears on the print 
through all colors.
Either the imaging unit or the fuser is 
scratched.
Replace the imaging unit; make sure that 
the old imaging unit is not exposed to light 
for more than 45 seconds.  
If a new imaging unit does not correct the 
problem:
Put the old imaging unit back into the 
printer.
Repack the new imaging unit.
Replace the fuser.
Front panel reports:
Fuser:replace
The fuser is worn out.
Replace the fuser.
A piece of the printed image 
is missing and reappears out 
of place, approximately 
100 mm (4 in.) down on the 
page.
The fuser is worn out.
Replace the fuser.
Troubleshooting and print quality quick reference (cont’d.)
Symptom
Possible Causes
Solution
Print Quality Test Page
Cyan
Magenta
Yellow
Black
Count
Image Unit
1505
Corona
487
Transfer Kit
484
Fuser
0
Print Quality Test Page
Cyan
Magenta
Yellow
Black
Count
Image Unit
1505
Corona
487
Transfer Kit
484
Fuser
0