Lexmark X644e Reference Guide

Page of 120
Paper Menu
21
Using MFP menus
Configure MP
This menu item is used to configure the multipurpose feeder as another source or manual feeder. If the multipurpose feeder 
is linked with another tray, the MFP can select print media from the multipurpose feeder before selecting print media from 
another tray.
Envelope Enhance
Use this setting to disable the optional envelope conditioner hardware when printing envelopes. This hardware significantly 
lessens the wrinkling or creasing of some envelopes.
Note: When printing envelopes a bubble may form between the envelope layers. When the bubble reaches 
the end of the envelope during the fusing process, a wrinkle or crease forms. To prevent this situation, 
pressure on a roller in the fuser is released periodically. This is envelope conditioning.
Menu item
Purpose
Values and descriptions
Configure MP
Determines when the MFP selects 
print media loaded in the multipurpose 
feeder.
Cassette*
MFP treats the multipurpose feeder 
like any other tray. If a print job 
requests a size or type that is only 
loaded in the multipurpose feeder, 
the MFP pulls print media from the 
multipurpose feeder for the job.
Manual
MFP treats the multipurpose feeder 
like a manual feed tray, and 
Load 
Manual
 appears when a single 
sheet of print media needs to be 
inserted in the feeder.
First
MFP pulls print media from the 
multipurpose feeder until it is 
empty, regardless of the source or 
size requested for the job.
Menu item
Purpose
Values and descriptions
Envelope Enhance
Disables the optional envelope 
conditioner hardware.
On*
Off
This menu item is shown if optional 
envelope conditioner hardware is 
installed.
Turning Envelope Enhance to Off does 
not allow the fuser to release pressure 
during fusing.