TOA a-9060dh User Guide

Page of 138
88
Follow the procedures below to return all settings to default values while using the unit in the matrix mode.
Details of the default values are shown on 
12. RESTORING FACTORY DEFAULT SETTING
I N I T I A L I Z E   O K ?        
S T E R E O   L I N K              
                             
Normal use state
Memory initialization screen
M E M O R Y                        
Memory
1
2
4
I N I T I A L I Z E P R O G R E S S
.
       
                   
0 1
S C E N E
0 1
S C E N E
UTILITY
ENTER
3
Step 1. Press the Utility key to display the utility setting screen.
Step 2. Press the Up or Down shift key until the "MEMORY"
indication is displayed.
Step 3. Press the Right shift key to display the memory
initialization screen "INITIALIZE OK?" indication.
Step 4. When "INITIALIZE OK?" is displayed, press the Enter key.
To cancel initialization, press the Up or Down shift key to
move to the next setting screen.
After initialization completion, the unit returns to the normal
use state.