Intel S5000XAL BB5000XALR User Manual

Product codes
BB5000XALR
Page of 112
Jumper Block Settings 
Intel
®
 Server Board S5000PAL / S5000XAL TPS 
 
 
Revision 1.9 
Intel order number: D31979-010 
60 
6. Jumper 
Block 
Settings 
The server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or 
recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “▼”. 
6.1  Recovery Jumper Blocks 
Table 32. Recovery Jumpers (J1D1, J1D2, J1D3)  
Jumper Name 
Pins  
What happens at system reset… 
1-2 
BMC Firmware Force Update Mode – Disabled (Default) 
J1D1: BMC Force 
Update 
2-3 
BMC Firmware Force Update Mode – Enabled 
1-2 
These pins should have a jumper in place for normal system operation.  (Default) 
J1D2: Password 
Clear 
2-3 
If these pins are jumpered, administrator and user passwords will be cleared 
immediately. These pins should not be jumpered for normal operation. 
1-2 
These pins should have a jumper in place for normal system operation.  (Default) 
J1D3: CMOS 
Clear 
2-3
 
If these pins are jumpered, the CMOS settings will be cleared immediately. These pins 
should not be jumpered for normal operation 
 
TP02080
3
2
Password
Reset
J1D2
J1D3
3
2
Clear
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable
 
Figure 17.  Recovery Jumper Blocks (J1D1, J1D2, J1D3)