Jumper Block Settings
Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision 1.9
Intel order number: D31979-010
60
6. Jumper
Block
Settings
The server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “▼”.
recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “▼”.
6.1 Recovery Jumper Blocks
Table 32. Recovery Jumpers (J1D1, J1D2, J1D3)
Jumper Name
Pins
What happens at system reset…
1-2
BMC Firmware Force Update Mode – Disabled (Default)
J1D1: BMC Force
Update
Update
2-3
BMC Firmware Force Update Mode – Enabled
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D2: Password
Clear
Clear
2-3
If these pins are jumpered, administrator and user passwords will be cleared
immediately. These pins should not be jumpered for normal operation.
immediately. These pins should not be jumpered for normal operation.
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D3: CMOS
Clear
Clear
2-3
If these pins are jumpered, the CMOS settings will be cleared immediately. These pins
should not be jumpered for normal operation
should not be jumpered for normal operation
TP02080
3
2
Password
Reset
Reset
J1D2
J1D3
3
2
Clear
CMOS
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable
Figure 17. Recovery Jumper Blocks (J1D1, J1D2, J1D3)