Jumper Block Settings 
Intel
®
 Server Board S5000PAL / S5000XAL TPS 
 
 
Revision 1.9 
Intel order number: D31979-010 
62 
Note:
 Normal BMC functionality is disabled with the force BMC update jumper set to the “enabled” 
position. The server should never be run with the BMC force update jumper set in this position and should 
only be used when the standard firmware update process fails. This jumper should remain in the default – 
disabled position when the server is running normally.  
6.2  BIOS Select Jumper 
The jumper block at J3H1, located just to the left of the SSI control panel header, is used to select which 
BIOS image the system will boot to. Pin 1 on the jumper is identified with a ‘▼’. This jumper should only 
be moved if you wish to force the BIOS to boot to the secondary bank which may hold a different version 
of BIOS.   
TP02305
J3H1
2
3
2
3
1-2: Force BIOS
to bank 0
2-3: System is
configured for
normal operation
(factory default)
 
Figure 18. BIOS Select Jumper (J3H1) 
Pins  
What happens at system reset… 
1-2 
Force BIOS to a alternative bank 
2-3 
System is configured for normal operation (Default) 
 
BIOS update is supported when the Recovery Jumper is either set on pins 1-2 (recovery mode), or pins 
2-3 (normal mode).  
To perform a normal BIOS update, follow the below steps: 
1. Boot the system with the jumper covering pins 2 and 3. 
2. Update the BIOS using iFlash or the Intel® One Flash Update (OFU) utility. 
3. Reset the system. 
4. The system will boot from the new BIOS. 
If the system can not boot, perform the below steps to recover: 
1. Boot the system with the jumper covering pins 1 and 2. 
2. Update the BIOS using iFlash or the Intel® One Flash Update (OFU) utility. 
3. Power down the server and unplug the AC power cord. 
4. Move the recovery jumper back to the normal position. 
5. Plug in the power cord and power on the system. 
6. The system will boot from the new BIOS.