D-Link DMI-128ESU User Manual

Page of 61
D-LINK ISDN TA DMI-128ESU+ 
32 
AT&F 
Recall factory default setting 
 
The factory configuration contained in the 
ROM is loaded to become the TA’s 
configuration. 
AT&Kn 
Flow control 
  *3 
    4 
•  No flow control 
•  Hardware flow control (RTS/CTS) 
•  Software flow control (Xon/Xoff) 
AT&Sn 
DR signal control 
Defines how the DSR (DR) signal is 
handled by the TA 
  *0 
 
    1 
•  TA‘s DSR (DR) signal follows DTE’s  
        DTR 
•  DSR (DR) signal on at only   
communication time. 
      (DSR signal high during        
      communication time) 
AT&Vn 
Display system configuration  
Cause the TA to display its current 
configuration 

•  Displays the current 
configuration 
•  Display Directory Numbers and all  
        stored phone numbers 
AT&Wn 
Write user profile 
The TA ‘s active configuration will 
be stored into the non-volatile 
memory as User profile  

•  Write user profile 0 
•  Write user profile 1 
AT&Yn 
Load user configuration when power on 

 
•  Use user profile 0 as active Profile 
when power up 
•  Use user profile 1 as active Profile 
when power up 
AT&Zn=x 
Register speed dial number 
n  
•  n = 0-19 
•  x = telephone number 
AT%A2=n 
Data port protocol selection 
Select the protocol on BOD channel 


  *5 

  14 
•  V.110 
•  V.120 
•  X.25 on D 
•  PPP 
•  MLPPP 
•  X.75 
•  Channel Bundling 
AT%A5=n 
Enbloc/overlap sending mode  
Select the sending method for telephone 
number (refer also AY*W0, AT*W1) 
  *0 
 
 
•  Overlap sending 
The dialing telephone will be sent to 
network after TA detect the ending digit 
•  Enbloc sending 
The dialing telephone number will be 
sent to network immediately whenever 
the user dialing each digit  
AT%D 
Data port setting display 
 
Display all corresponding setting 
AT%DC 
Show disconnect cause, source, charge 
 
Display the disconnect reason and 
connection fee 
AT%FAPPS 
Re-Flash the new software 
 
 
AT%N=x 
Set data port directory number / sub-
address  
(eg. AT%N=12345678 + 12345) 
    x 
•  x=telephone number 
       main - address: max 20 digits 
       sub - address: max 5 digits 
AT%Sn 
Data port call screen function enable 
 
  *1 
•  Accept incoming call if the calling 
        party number is in the call screen table. 
•  Accept all incoming call 
AT%Z1 
Software reset 
 
Reset all internal state of TA 
AT$AAn 
Set analog port A voice information 
capability in answer mode  

  *2 
•  Accept speech 
•  Accept 3.1kHz audio 
•  Accept both 
AT$AN=x 
Set analog port A directory number / sub-
address (Not used in Finland) 
Eg. AT$AN1234567812345 
    x 
•  X = telephone number 
Main - address: max 20 digits 
        Sub - address: max 5 digits